LPC Interface Routing Summary

Trace
Impedance
55 Ω ± 10%
9.8

SMBus 2.0/SMLink Interface

The SMBus interface on the 6300ESB uses two signals SMBCLK and SMBDATA to send and
receive data from components residing on the bus (see
exclusively by the SMBus Host Controller. The SMBus Host Controller resides inside the
6300ESB.
The 6300ESB incorporates a SMLink interface supporting Alert on LAN*, Alert on LAN2* and a
slave functionality. It uses two signals SMLINK [1:0]. SMLINK[0] corresponds to an SMBus
clock signal and SMLINK[1] corresponds to an SMBus data signal. These signals are part of the
SMB Slave Interface.
For Alert on LAN* functionality, the 6300ESB transmits heartbeat and event messages over the
interface. When using the Intel
claim the SMLink heartbeat and event messages and send them out over the network. An external,
Alert on LAN2*-enabled LAN Controller (e.g., Intel 82562EM/82562EX 10/100 Mbps Platform
LAN Connect) will connect to the SMLink signals to receive heartbeat and event messages, as well
as access the 6300ESB SMBus Slave Interface. The slave interface function allows an external
microcontroller to perform various functions. For example, the slave write interface may reset or
wake a system, generate SMI# or interrupts, and send a message. The slave read interface may read
the system power state, read the watchdog timer status, and read system status bits.
®
6300ESB ICH Embedded Platform Design Guide
LPC Routing
Requirements
5 mil width, 12 mil
L1 = 2 to 8 inches
spacing (based on
L2 = 0 to 6 inches
stackup assumptions
L3 =0 to 6 inches
in
Section
3.1)
®
82562EM/82562EX Platform LAN Connect Component, it will
January 2007
®
Intel
6300ESB Design Guidelines
Trace Lengths
LPC Clock Length Matching
No more than 0.25 inches (250 mils)
difference between clock signals.