Allen-Bradley 1444-TSCX02-02RB User Manual page 481

Monitoring system
Table of Contents

Advertisement

Table 226 - Advanced CM Data Request Parameters (continued)
25
Number of
Averages
26
Waveform Record
Length
27
FFT Line Resolution
28
FFT Window
Function
29
FFT Line Value
Scaling
30
Pad
Instance 4 (Channel 3)
32
Enable
33
Number of
Averages
34
Waveform Record
Length
35
FFT Line Resolution
36
FFT Window
Function
37
FFT Line Value
Scaling
38
Pad
Table 227 - Record Length
Index
TWF Samples
8
65536
7
32768
6
16384
5
8192
4
4096
3
2048
2
1024
1
512
0
256
(1) The Base FFT Lines represent the size of the raw processed FFT and are the number of lines returned if no adjustments are made
for decimation and filtering. Control of application of relevant factors for the applied decimation and filtering is provided in the
SpecialRequest member of the CM Record Request structure
(2) Or if -60 dB filter is applied (Aeroderivative Measurement Type)
(3) And the standard -24 dB/octave filter is applied.
Rockwell Automation Publication 1444-UM001D-EN-P - June 2018
SINT
Identical control to the control used in the Normal CM Data
Object (0x30A).
SINT
Defines the number of samples in the Advanced CM, waveform.
SINT
dentical control to the control used in the Normal CM Data
I
Object (0x30A), but with additional indices. See
page
481.
SINT
Identical control to the control used in the Normal CM Data
Object (0x30A).
SINT
Allows line/bin values to be returned scaled as Peak, Peak to
Peak, or RMS [0 Peak, 1 Peak to Peak, 2 RMS].
INT
Used to align data to a 32 bit boundary.
BYTE
A bit-wise enable control.
SINT
Identical control to the control used in the Normal CM Data
Object (0x30A).
SINT
Defines the number of samples in the Advanced CM, waveform.
SINT
Identical control to the control used in the Normal CM Data
Object (0x30A), but with additional indices. See
page
481.
SINT
Identical control to the control used in the Normal CM Data
Object (0x30A).
SINT
Allows line/bin values to be returned scaled as Peak, Peak to
Peak, or RMS [0 Peak, 1 Peak to Peak, 2 RMS].
INT
Used to align data to a 32 bit boundary.
Decimation
Base FFT
Decimation
(1)
Lines
None
-
-
12800
14400
6400
7200
3200
3600
1600
1800
800
900
400
450
200
225
100
112
(Table
230).
CIP Objects
Appendix A
Table 227 on
Table 227 on
Alternate
Primary
(2)
(3)
Path
Path
-
-
8000
4800
4000
2400
2000
1200
1000
600
500
300
250
150
125
75
67
32
481