Allen-Bradley 1444-TSCX02-02RB User Manual page 437

Monitoring system
Table of Contents

Advertisement

General Order Setup
For one byte, bit-wise control is used to allow for enabling individual tracking
filters and to assign a tacho channel.
Four 2-bit arrangements are used.
Bit
Description
0
Tracking filter 0
0: Enable; 1: Disabled
Default: Enabled
1
Tracking filter 0
0: Tacho 0; 1: Tacho 1
Default: Tacho 1
2
Tracking filter 1
0: Enable; 1: Disabled
Default: Enabled
3
Tracking filter 1
0: Tacho 0; 1: Tacho 1
Default: Tacho 1
4
Tracking filter 2
0: Enable; 1: Disabled
Default: Enabled
5
Tracking filter 2
0: Tacho 0; 1: Tacho 1
Default: Tacho 1
6
Tracking filter 3
0: Enable; 1: Disabled
Default: Enabled
7
Tracking filter 3
0: Tacho 0; 1: Tacho 1
Default: Tacho 1
Table 170 - Common Services
Service
Implementation
Code
Class
Instance
0x0E
x
x
Rockwell Automation Publication 1444-UM001D-EN-P - June 2018
Service Name
Description of Service
Get Attribute Single
Returns the contents of the specified attribute
Get requests to certain attributes require data to
be requested from the auxiliary module itself. If
that module is not present/active on the bus, an
embedded server error is returned in response to
the request.
CIP Objects