Appendix A
CIP Objects
Table 83 - Parameter – Tag – Object Attribute Cross-reference (continued)
Parameter
Fault Mode Output State
Measurement Alarm Page
Enable Alarm
Alarm Name
Measurement
Condition
Transducer Fault Behavior
Deadband
Alert Alarm Delay Time
Danger Alarm Delay Time
Apply Limits From
Danger High Limit
Alert High Limit
Alert Low Limit
Danger Low Limit
Danger High Output Tag Limit
Alert High Output Tag Limit
Alert Low Output Tag Limit
Danger Low Output Tag Limit
Limit Multiplier
Control Parameter
High Limit
Multiplier
Voted Alarm Page
Alarm Name
Alarm Status to Activate On – Alert
Alarm Status to Activate On – Danger
Alarm Status to Activate On –
Transducer Fault
Measurement Alarm – Input 0
Measurement Alarm – Input 1
322
Tag Member
Ch0...3AnalogOut.FaultValue
MeasAlarm00...23.En
MeasAlarmName00_04[x0...4]
MeasAlarmName05_11[0...6]
MeasAlarmName12_18[0...6]
MeasAlarmName19_23[0...4]
MeasAlarm00...23.ID
See
Measurement ID Definition on page
MeasAlarm00...23.Condition
MeasAlarm00...23.SensorFaultAction
MeasAlarm00...23.AlarmDeadband
MeasAlarm00...23.AlertDelayTime
MeasAlarm00...23.DangerDelayTime
MeasAlarm00...23.LimitMode
MeasAlarm00...23.HDangerAlarmLimit
MeasAlarm00...23.HAlertAlarmLimit
MeasAlarm00...23.LAlertAlarmLimit
MeasAlarm00...23.LDangerAlarmLimit
MeasAlarm00...23.HDangerAlarmOutputRef
MeasAlarm00...23.HAlertAlarmOutputRef
MeasAlarm00...23.LAlertAlarmOutputRef
MeasAlarm00...23.LDangerAlarmOutputRef
MeasAlarm00...23.LimitMultiplier
MeasAlarm00...23.AdaptiveSource
MeasAlarm00...23.Range0...4HLimit
MeasAlarm00...23.Range0...4Multiplier
VotedAlarmName00_01[0...1]
VotedAlarmName02_08[0...6]
VotedAlarmName09_12[0...3]
VotedAlarm00...13.AlarmOnAlert
VotedAlarm00...13.AlarmOnDanger
VotedAlarm00...13.AlarmOnTransducerFault
VotedAlarm00...13.Alarm0Input
VotedAlarm00...13.Alarm1Input
Rockwell Automation Publication 1444-UM001D-EN-P - June 2018
Object
Dynamix Current Output Module
Object
Dynamix Measurement Alarm Object Alarm Enable
Dynamix Measurement Alarm Object Alarm Name
Dynamix Measurement Alarm Object Alarm Name
Dynamix Measurement Alarm Object Alarm Name
Dynamix Measurement Alarm Object Alarm Name
Dynamix Measurement Alarm Object Alarm Measurement Identifier
325.
Dynamix Measurement Alarm Object Alarm Form
Dynamix Measurement Alarm Object Alarm Type
Dynamix Measurement Alarm Object Hysteresis
Dynamix Measurement Alarm Object Delay/Sustain Time (Alert)
Dynamix Measurement Alarm Object Delay/Sustain Time (Danger)
Dynamix Measurement Alarm Object Alarm Processing Mode
Dynamix Measurement Alarm Object High Danger Threshold
Dynamix Measurement Alarm Object High Alert Threshold
Dynamix Measurement Alarm Object Low Alert Threshold
Dynamix Measurement Alarm Object Low Danger Threshold
Dynamix Measurement Alarm Object Profile mode - Reference for High
Dynamix Measurement Alarm Object Profile mode - Reference for High
Dynamix Measurement Alarm Object Profile mode - Reference for Low
Dynamix Measurement Alarm Object Profile mode - Reference for Low
Dynamix Measurement Alarm Object Alarm Multiplier
Dynamix Measurement Alarm Object Adaptive Monitoring Source
Dynamix Measurement Alarm Object Range 0...4 – upper control value
Dynamix Measurement Alarm Object Range 0...4 – Alarm Multiplier
Dynamix Voted Alarm Object
Dynamix Voted Alarm Object
Dynamix Voted Alarm Object
Dynamix Voted Alarm Object
Dynamix Voted Alarm Object
Dynamix Voted Alarm Object
Dynamix Voted Alarm Object
Dynamix Voted Alarm Object
Attribute
Current Output Not OK Configuration
Danger Threshold
Alert Threshold
Alert Threshold
Danger Threshold
Alarm Name
Alarm Name
Alarm Name
Alarm Usage
Alarm Usage
Alarm Usage
Alarm Input 0
Alarm Input 1