Allen-Bradley 1444-TSCX02-02RB User Manual page 435

Monitoring system
Table of Contents

Advertisement

Table 169 - Instance Attributes (continued)
17
Get
V
Order
Measurement
Units
18
Get
V
Order
Measurement
Scaling
19
Get
V
Tracking Filter
Mode
20
Get
V
Tracking Filter
Definition
(Tacho 0)
21
Get
V
Tracking Filter
Definition
(Tacho 1)
24
Get
V
Order Update
Rate (Tacho 0)
25
Get
V
Order Update
Rate (Tacho 1)
Order Requirement Definitions
32
Get
V
Tracking filter 0
setup
Rockwell Automation Publication 1444-UM001D-EN-P - June 2018
CIP Objects
ENGUNITS
Definition of
measurement
engineering units that
indirectly also allow for
signal integration/
differentiation.
SINT
The scaled
measurement
detection that is used
for the order
assessments.
SINT
Define order signal
processing-mode.
REAL
The filter Q factor or
Frequency bandwidth
that is associated with
the selected processing
mode.
REAL
The filter Q factor or
Frequency bandwidth
that is associated with
the selected processing
mode.
REAL
Approximation of the
anticipated order
measurement update
rate that is based on
signal processing and
order setup.
REAL
Approximation of the
anticipated order
measurement update
rate that is based on
signal processing and
order setup.
Group of four configuration attributes.
REAL
Order 0 Definition -
integer values return
Mag/Phase as where
only Mag is returned
for non-integer
settings.
Appendix A
Options and selection
criteria
0: Peak
1: pk-pk
2: RMS
0: Constant Q
1: Fixed frequency
Currently only fixed Q
mode
supported, by
specifying a number of
revolutions.
Default: 10
Range: 1...256
Separate definitions to
support different
settings in Fixed
frequency mode. For
fixed Q mode, the AOP
sets 20 and 21 equal.
Seconds
Seconds
0.25...32.0 orders
default value 1.0