Attribute Semantics - Allen-Bradley 1444-TSCX02-02RB User Manual

Monitoring system
Table of Contents

Advertisement

Appendix A
CIP Objects
Table 146 - Instance Attributes (continued)
27
Get
V
28
Get
V
TX OK Detection
32
Get
V
33
Get
V
34
Get
V
416
Transducer DC sensitivity
REAL
TX Power Setup
SINT
Group of three configuration attributes.
Transducer OK Configuration
BYTE
Transducer OK High Threshold
REAL
Transducer OK Low Threshold
REAL

Attribute Semantics

TX OK Configuration Decoding
Bit
0
1
2
3
For Module Personality "Real Time - 2 Dynamic (4 kHz) - Dual Path":
Dual path uses both channel pairs to process one pair of transducer signals
without requiring external linking of the signal inputs. The sensors are
connected normally to channels 0 and 1 but are processed by both channel
pairs (channel 0 to channel 2, and channel 1 to channel 3). Consequently only
channels 0 and 1 are used for transducer status.
'Wire off ' refers to additional failure sensing applied to Eddy Current Probe
systems that are powered by the module. Wire off is only incorporated into
Transducer Fail when specific configuration criteria are met. If those criteria are
not met and/or the capability has been disabled by setting attribute 32 to a
nonzero value, then bit 3 is forced OK (zero value). If the wire off detection
capability is being actively used, then if a transducer fail is indicated, the value
of bit 3 confirms if a wire off has been detected. There is the possibility of
multiple checks (simultaneously) triggering an indication of transducer failure.
Rockwell Automation Publication 1444-UM001D-EN-P - June 2018
Transducer DC sensitivity in mV/
Range: 1...20000
TX DC units.
Coded configuration for sensor
Transducer OK Configuration
power supply configuration.
Definition is independent of the
selected transducer/application
type.
Definition of which conditions are
Transducer OK Configuration
included in a TX OK assessment
High-voltage threshold for the TX
V
OK monitoring window
Range: 22...-21
Low voltage threshold for the TX
V
OK monitoring window
Range: 22...-21
Description (When bit Is Set = 1)
Channel enabled
Transducer enabled
Transducer fault
Wire off indicated

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents