Table 258 - Class Attributes (continued)
Attribute ID
Access Rule
20
Get
21
Get
22
Get
23
Get
Main Module Tacho
24
Get
Main Module Opto Outputs 0/1
32
Get
33
Get
Main Module Local Onboard Relay
39
Get
40
Get
41
Get
42
Get
43
Get
44
Get
64
Get
Channel 0 DSP FFT
72
Get
73
Get
NV
Name
NV
NetX Firmware Build
NV
DSP Firmware Build
-
DSP Configuration CRC
-
NetX/DSP Error Status
V
Tacho Mode
V
Opto Output 0 Allocation
V
Opto Output 1 Allocation
V
Auto Local Relay Control
NV
User Local Relay Control
NV
Local Relay Control
V
Relay Source
V
Relay Drive Test Enable
V
Relay Drive Test
Interval
V
Redundant Power Supply
V
Enable
V
Signal Source
Rockwell Automation Publication 1444-UM001D-EN-P - June 2018
Data Type
Description of Attribute Semantics of Values
SHORT-STRING
Build Date (ASCII string)
UDINT
Build Version
UINT
16-bit CRC for the DSP and
Auxiliary relevant
configuration
DWORD
DSP: bits 0...15 NetX: bits
16...31
A configuration attribute.
SINT
Individual or Redundant
Mode
A group of two configuration attributes.
SINT
Source configuration for
this Opto-isolated output.
SINT
Source configuration for
this Opto-isolated output.
A logical grouping of parameters.
BYTE
Configuration of local relay
behavior in case of
detected fault condition,
which is based on
associated voted alarm.
BYTE
User configuration of local
relay behavior in case of
detected fault condition.
BYTE
Actual behavior of local
relay in case of detected
fault condition.
SINT
Link to corresponding
voted alarm object
(instance and output
type).
BOOL
Whether the relay drive
circuit is being routinely
tested.
UINT
Test interval.
SINT
Whether the module is
being powered
redundantly.
Group of seven configuration attributes.
SINT
An enable control. Only
enable if FFT bands are
required from this channel.
SINT
Defines the data source.
CIP Objects
Appendix A
for example, length 0x0B 56, 65, 70,
20, 31, 37
Sep 17
20, 32, 30, 31, 34
2014
for example, 10034 is V1.00.34
Is unchanged if configuration
changes are limited to CM features
Normal (no error) status = 0
Bit 0 - DSP Not responding
Bit 1 - DSP in boot loader mode
Bit 2 - Configuration process failed
to complete
Bit 16 - Corrupt object file detected
0: Individual
else Redundant Tacho Mode
Opto source
Opto source
Returns 0 if relay source is not a
voted alarm
Relay control
Relay control
Relay control
Relay source decoding
Automatic on fail-safe setting
ms
0: Not redundant
1: Redundant
0: Disable
1: Enable
Source
507