Lower Module Connector - Allen-Bradley 1444-TSCX02-02RB User Manual

Monitoring system
Table of Contents

Advertisement

Chapter 2
Install the Dynamix 1444 Series Monitoring System
62
Buffered Outputs
Along with the BNC outputs, a buffered output is provided for each channel
(0...3) on the upper module connector.
48
47
46
BUFF0
RET
BUFF1
Although having independent resistive current limiting, the buffered and BNC
outputs of any one channel share drive circuitry. All signal-related inputs and
outputs, unless otherwise indicated, share analog ground/return.
Table 9 - Buffered Output Resistance
Buffered
Resistance
Output
()
BNC
100
Terminal
100
Pins
Notes
All outputs are single ended and have no isolation.
Buffered output is not representative of input when no load (sensor) is connected to the associated
measurement channel.
Confirm that the connected instrumentation does not provide power, such as if to power an
accelerometer, to the buffer output.

Lower Module Connector

The following are functions of the lower module connector.
Sensor Connections
The sensor connections are made on the lower module connector.
Terminal
Name
1
TXP0
2
SIG0
3
SIG0
4
RET0
5
TXP1
6
SIG1
7
SIG1
8
RET1
Rockwell Automation Publication 1444-UM001D-EN-P - June 2018
45
44
RET
BUFF2
Protection
Use/Application
ESD/EFT Surge
Yes
No
For temporary connection to instruments such as portable
data collectors or analysis systems over short distances (10
m/32 ft).
Yes
Yes
For permanent connections to instruments or when long
cable runs (100 m/328 ft) are required.
Application
Sensor 0
Sensor 1
43
42
41
RET
BUFF3
RET
Description
Transducer 0 Power
Transducer 0 Signal
Transducer 0 Return
Transducer 1 Power
Transducer 1 Signal
Transducer 1 Return

Hide quick links: