Allen-Bradley 1444-TSCX02-02RB User Manual page 385

Monitoring system
Table of Contents

Advertisement

Table 113 - Instance Attributes (continued)
Attribute ID
Access
NV
Rule
7
Get
V
8
Get
V
9
Get
V
Update Rates
17
Get
NV
18
Get
NV
19
Get
NV
Trend Data Storage
24
Get
V
Alarm Data Storage
32
Get
V
33
Get
V
34
Get
V
35
Get
V
36
Get
V
Static Data Source
48
Get
V
49
Get
V
50
Get
V
51
Get
V
Name
Data Type
Alarm Overall (High Resolution)
UINT
Data Records
Alarm Overall (Low Resolution)
UINT
Data Records
Alarm Dynamic Data Records
UINT
Group of 3 configuration attributes
Trend Overall Update Multiplier
INT
Trend Dynamic Update Multiplier DINT
Alarm Overall Update Multiplier
INT
A configuration attribute
Trend Data-Set Enable
BYTE
Group of 5 configuration attributes
Alarm Data Storage Trigger
SINT
Source
Alarm Data Storage Latching
SINT
Alarm % Post Trigger for the
SINT
High Resolution
(100 ms) Overall Records
Alarm % Post Trigger for the Low
SINT
Resolution (Configured Rate)
Overall Records
Alarm % Post Trigger for
SINT
Dynamic Data Records (10x
Configured Overall Rate)
A group of 4 DWORDs where each bit indicates whether that measurement is included or not.
DWORD 0
DWORD
DWORD 1
DWORD
DWORD 2
DWORD
DWORD 3
DWORD
Rockwell Automation Publication 1444-UM001D-EN-P - June 2018
Description of Attribute
Semantics of Values
Returns the number of overall data
Fixed depth: 320
records (at the fast update rate)
that the buffer currently holds.
Returns the number of (low
Fixed depth: 640
resolution) overall data records
that the buffer currently holds.
Returns the number of dynamic
Fixed depth: 64
data records that the buffer
currently holds.
The rate at which Trend Overall
Multiples of 100 ms
data records are stored, based on
Default of 10
the fast update rate.
Range: 1...32767
The rate at which Trend Dynamic
Multiples of 100 ms
data records are stored, based on
Default of 100
the fast update rate.
Range: 10...327670
Defines overall record update rate
Equal to Attribute 17
for use in alarm storage, which is
Range: 1...32767
based on the fast update rate.
Activate Trend Storage on a per
Bit enabled control. See
channel basis
Enable" under Attribute Semantics.
Reference to Voted Alarm Object,
including OFF option.
If latching, the alarm data buffer
0: Not latching
does not update on subsequent
1: Latching
alarm excursions unless the latch
has been reset.
Overall, post-trigger setting for the
Range: 0...8
100 ms update rate - set in eighths
Default: 2 (25%)
of the total buffer length
(80 / 320 records)
Overall, post-trigger setting for the
Range: 0...8
user configured update rate - set in
Default: 2 (25%)
eighths of the total buffer length
(160 / 640 records)
Overall, post-trigger setting for the
Range: 0...8
dynamic data records - set in
Default: 2 (25%)
eighths of the total buffer length
(16 / 64 records)
Range: 0...4294967295
Range: 0...4294967295
Range: 0...4294967295
DWORD 3 is only partially
Range: 0...1023
populated with measurements,
hence the lower range.
CIP Objects
Appendix A
"Trend Data-Set
385