Dynamix Dual; Measurement Object - Allen-Bradley 1444-TSCX02-02RB User Manual

Monitoring system
Table of Contents

Advertisement

Appendix A
CIP Objects
Dynamix Dual 

Measurement Object

Table 164 - Instance Attributes
Attribute ID
Access Rule
1
Get
2
Get
5
Get
6
Get
8
Get
9
Get
Differential Expansion
16
Get
17
Get
18
Get
19
Get
430
This Dual Measurement Object (class code 0x392) defines, in combination
with the selected application type in measurement channel setup, the
additional behavior of the fixed channel pairs.
It provides access to available Dual Channel measurement results and defines
channel pair-specific configuration parameters for differential expansion.
Table 162 - Object Instances
Instance ID
0
1
2
Table 163 - Class Attributes
Attribute
Access
ID
Rule
1
Get
NV
Name
V
SMAX Peak
V
Phase angle of the SMAX Peak
Vector
V
Axial Differential Expansion
V
Radial Ramp Diff Expansion
V
Shaft Abs Vib Peak
V
Shaft Abs Vib pk-pk
V
Sensor A Ramp Angle
V
Sensor B Ramp Angle
V
Overall Axial Offset
V
Overall Radial Offset
Rockwell Automation Publication 1444-UM001D-EN-P - June 2018
Description
Dual Measurement Class Instance
Instance 1 for transducer pair 0...1
Instance 2 for transducer pair 2...3
NV
Name
Data
Type
NV
Revision
UINT
Data Type
Description of Attribute
REAL
Processed SMAX Peak output.
REAL
Phase angle of attribute 1.
REAL
Processed axial differential expansion
output (CDE or Ramp).
REAL
Processed radial differential expansion
output (ramp only).
REAL
Processed shaft abs vib pk output.
REAL
Processed shaft abs vib pk-pk output.
Group of four configuration attributes.
REAL
Ramp angle for sensor input A in
degrees.
REAL
Ramp angle for sensor input B in
degrees.
REAL
An overall (axial) offset in DC
measurement units.
REAL
An overall (radial) offset in DC
measurement units.
Description of
Semantics of Values
Attribute
Current object revision.
Current revision.
Semantics of Values
0 output when not an XY
application
0 output when not an XY
application
0 output when not configured
0 output when not configured
0 output when not configured
0 output when not configured
Setup information
Setup information
Applicable to Ramp and CDE
applications
Range: -50000...50000
Ramp only
Range: -25000...25000

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents