Operate the Module
Tag
Transient0CaptureStatus
Transient Buffer 0 Status
Transient1CaptureStatus
Transient Buffer 1 Status
Transient2CaptureStatus
Transient Buffer 2 Status
Transient3CaptureStatus
Transient Buffer 3 Status
268
Table 53 - Transient Status
4 bit status
Value
Description
0
Free
1
Data Ready Normal
2
Data Latched Normal
3
Transient In Progress RPM
4
Transient In Progress Time
5
Data Ready Aborted
6
Data Latched Aborted
7
Data Ready time-out
8
Data Latched time-out
Same as previous
Rockwell Automation Publication 1444-UM001D-EN-P - June 2018
Description (if = 1)
Available / ready for transient event.
Transient completed normally, could be
overwritten by a new event.
Transient completed normally, buffer latched.
Delta RPM data acquisition in progress.
Delta Time data acquisition in progress.
Speed that is returned above/below the
initiating threshold, could be overwritten by
a new event.
Speed that is returned above/below the
initiating threshold, could be overwritten by
a new event.
Speed that is crossed the initiating threshold
that is then timed out, could be overwritten
by a new event.
Speed that is crossed the initiating threshold
that is then timed out, buffer latched.