CIP Objects
480
The data that is sent with an Advanced CM data request is divided into two
separate sections, the class section, and four instance sections. This process is
similar to how EtherNet/IP classes are constructed with one class instance and
multiple 'instance' instances.
The host sends the following Advanced CM Data Request Parameters as part
of an 0x4B service request.
Table 226 - Advanced CM Data Request Parameters
Byte Offset
Structure
Within
Member
Structure
Class Instance
0
Pad
1
Advanced Session
Timeout
2
Advanced Session
Instance
4
Sync Data Control
Instance 1 (Channel 0)
6
Pad
9
Number of
Averages
10
Waveform Record
Length
11
FFT Line Resolution
12
FFT Window
Function
13
FFT Line Value
Scaling
14
Pad
Instance 2 (Channel 1)
16
Enable
17
Number of
Averages
18
Waveform Record
Length
19
FFT Line Resolution
20
FFT Window
Function
21
FFT Line Value
Scaling
22
Pad
Instance 3 (Channel 2)
24
Enable
Rockwell Automation Publication 1444-UM001D-EN-P - June 2018
Data
Description
Type
USINT
-
USINT
Seconds to have ownership of Advanced CM setup.
UINT
Set to 0, unless restarting an existing (unexpired) request, where
you' d pass in the Advanced Session Instance from the previous
response.
UINT
Used to request synchronized data from multiples modules.
WORD
Used to align data to a 32 bit boundary.
SINT
Identical control to the control used in the Normal CM Data
Object (0x30A).
SINT
Defines the number of samples in the Advanced CM, waveform.
SINT
Identical control to the control used in the Normal CM Data
Object (0x30A), but with additional indices. See
page
481.
SINT
Identical control to the control used in the Normal CM Data
Object (0x30A).
SINT
Allows line/bin values to be returned scaled as Peak, Peak to
Peak, or RMS [0 Peak, 1 Peak to Peak, 2 RMS].
INT
Used to align data to a 32 bit boundary.
BYTE
A bit-wise enable control.
SINT
Identical control to the control used in the Normal CM Data
Object (0x30A).
SINT
Defines the number of samples in the Advanced CM, waveform.
SINT
Identical control to the control used in the Normal CM Data
Object (0x30A), but with additional indices. See
page
481.
SINT
Identical control to the control used in the Normal CM Data
Object (0x30A).
SINT
Allows line/bin values to be returned scaled as Peak, Peak to
Peak, or RMS [0 Peak, 1 Peak to Peak, 2 RMS].
INT
Used to align data to a 32 bit boundary.
BYTE
A bit-wise enable control.