Operate the Module
Input: Sine-wave, 2 Vpp (-5 to -3V), ADC FMAX = 4578 Hz, No filtering
Measurements (volts RMS)
Values that are stated as "avg" are approximate as the measurement is varying by >10%
Frequency
TC=0.5 (Default)
OAO
60
1.98
50
1.98
40
1.97
30
1.94
20
1.91
15
1.87
10
1.83
9
1.81 avg
8
1.81 avg
7
1.75 avg
6
1.74 avg
5
1.68 avg
4
1.60 avg
3
1.52 avg
2
1.43 avg
1
0.85 avg
0.5
0.85 avg
0.25
0.60 avg
298
The results that are presented in
sine-wave input signal. Actual measurements of complex signals vary.
Table 73 - Input: Sine-wave, 2 Vpp
TC=30
OA1
OAO
2.02
2.02
2.02
2.02
2.02
2.02
2.02
2.02
2.03
2.02
2.02
2.02
2.02
2.02
2.02
2.02
2.02
2.02
2.01
2.02
2.02
2.01
2.02
2.01
2.03
2.01
2.02
2.01
1.98
2.00
2.20
1.98
1.75 avg
1.94 avg
1.70 avg
1.94 avg
OA0 = Post Filter, OA1 = Mid-Filter
Rockwell Automation Publication 1444-UM001D-EN-P - June 2018
Table 73
and
Table 74
TC=60
Tracking Filter
OA1
1xM
2.02
2.02
2.03
2.02
2.03
2.02
2.03
2.02
2.03
2.02
2.03
2.02
2.05
2.02
2.05
2.02
2.06
2.02
2.05
2.02
2.02
2.02
2.02
2.02
2.08
2.02
2.01
2.02
2.10
2.00
2.00
1.98
1.99 avg
1.80
1.99 avg
1.57
are based on a pure
RPM
1xP
81
3600
81
3000
81
2400
80
1800
80
1200
80
900
80
600
80
540
80
480
79
420
79
360
79
300
78
240
77
180
75
120
69
60
342
30
40
15

Hide quick links: