Table 19 - Hardware Configuration
Parameter
Values
Discrete Outputs
Parameter
Values
Pt0/1
-
-
0
1...13
17...29
33...45
48...49
50...51
52...53
54...55
56...59
127
Channel Type:
gSE
Input Tag
Measurement Type Selections
gSE
Channel Type:
Static (DC)
Input Tag
Measurement Type Selections
Rod Drop
Rod Drop
Differential Expansion
Comp. Differential Exp. A/B (Axial)
Differential Expansion
Ramp Differential Exp. A/B (Radial)
Rockwell Automation Publication 1444-UM001D-EN-P - June 2018
Configure the 1444 Dynamic Measurement Module
Comment
Comment
The 1444-DYN04-01RA includes two discrete opto-isolated outputs. These
provide output of selected status conditions or replication of selected
input signals. i
Function
Description
OFF
Output is not used.
Voted Alarm Instance 1...13 Alarm
The status of the selected Voted
Alert Status
Alarm when the alarm is configured
to activate on an alert condition.
Voted Alarm Instance 1...13 Danger
The status of the selected Voted
Alert Status
Alarm when the alarm is configured
to activate on danger conditions.
Voted Alarm Instance 1...13 Fault
The status of the selected Voted
Alert Status
Alarm when the alarm is configured
to activate on a transducer fault
condition.
Local TTL Tacho 0...1 Input
Replicated from the TTL signal that
is connected to the terminal pins.
Tacho Bus 0...1
Replicated from the TTL signal that
is communicated over the Local
Bus.
Tacho Bus 0...1 Fault
The Local Bus Tacho status.
Pt0...1 Discrete Input
Replicated from the Discrete Input.
Transducer 0...3 Fault
Transducer Status.
Module Status
Module Status.
Comment
Spike Energy (gSE) is a processing technique capable of detection of low
energy impacts. The measure is suitable for early detection of faults in
rolling element bearings or gears and detection of other periodic or
random low energy impact events.
Comment
A triggered position (rod-drop) measurement that is taken at a fixed
(consistently the same) position of the rod during the stroke.
The measurement of shaft axial displacement using a pair of axial eddy-
current-probe monitoring a shaft collar target such that the
measurement range is optimally the sum of the ranges of the individual
probes.
The measurement of differential expansion with axial/radial eddy-
current-probe pair viewing concave or convex ramp shaft.
Chapter 3
115