Maintenance Object Repair Procedures
Table 10-402. TEST #1379 Ping Test — Continued
Error
Test
Code
Result
2100
ABORT
2500
ABORT
2801
ABORT
2802
ABORT
2805
FAIL
2807
ABORT
7, 89,
FAIL
1007
PASS
NT Reset Test (#1381)
This test is destructive.
This test resets the circuit pack. The test is highly destructive and can only be
initiated by a system technician-demanded reset board UUCSS command.
10-1078
Issue 4 May 2002
Description/Recommendation
The necessary system resources to execute the test could not
be allocated.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
Internal system error.
1. Retry the command at 1-minute intervals a maximum
of 3 times.
No IP address defined. Verify IP Interfaces translations and
retest.
Different IP address pinged than software had allocated for the
test.
1. Retry the command at 1-minute intervals a maximum
of 3 times.
The number of pings received did not match the number sent
(normally one ping sent). This means that no ping responses
were received from the gateway defined on the ip-interfaces
form for the Media Processor.
1. Retry the command at 1-minute intervals a maximum
of 3 times.
The board is administered, but not enabled in the change
ip-interfaces form.
Ping to the destination failed through this port due to the
destination down.
1. Verify that at least one destination reachable through
this port is up.
2. Once verified, execute test port UUCSSpp command
to verify that the H.323 Signaling Group Ping Test
(#1387) passes.
Ping through this port successful.
Continued on next page