Ricoh Neptune-P1 Service Manual page 274

Table of Contents

Advertisement

4 Level 4
5 Level 5
1946
PreFBStp:TTD
This SP calculates the hot roller target temperature while pressure roller feedback control is
stopped. This SP determines the target hot roller temperature while pressure roller feedback
control is not operating. The temperature is determined based on the paper type and length of
the paper (Length Level).
Note: The Length Levels (1 to 5) are defined by SP1945.
1 LLvl1:Norm
2 LLvl2:Norm
3 LLvl3:Norm
4 LLvl4:Norm
5 LLvl5:Norm
11 LLvl1:Cold
12 LLvl2:Cold
13 LLvl3:Cold
14 LLvl4:Cold
15 LLvl5:Cold
16 LLvl0:Cold
1947
PreFB Stp:TP
This SP sets the length of time that pressure roller feedback is suspended for the paper lengths
defined by SP1945.
• Pressure roller feedback control begins when the time set with this SP has elapsed after
paper feed starts.
• As more paper is fed for a multiple print job, the time setting for succeeding sheets is
overwritten.
[1000 to 15000/9100/1 mm]
[1000 to 15000/12100/1 mm]
Pressure Roller Feedback Stop: Target Temperature
Differential
Length Level 1: Normal
Length Level 2: Normal
Length Level 3: Normal
Length Level 4: Normal
Length Level 5: Normal
Length Level 1: Cold Start
Length Level 2: Cold Start
Length Level 3: Cold Start
Length Level 4: Cold Start
Length Level 5: Cold Start
Length Level 0: Cold Start
Press FB Stop: Time Period
SP1-xxx Feed
o
[0 to 30/15/1
C]
o
[0 to 30/10/1
C]
o
[0 to 30/7/1
C]
o
[0 to 30/5/1
C]
o
[0 to 30/3/1
C]
o
[0 to 30/10/1
C]
o
[0 to 30/5/1
C]
o
[0 to 30/3/1
C]
o
[0 to 30/0/1
C]
5