Ricoh Neptune-P1 Service Manual page 250

Table of Contents

Advertisement

1 FeedM:R1 DFU
[-30 to +30/0/1]
For every change of "1", speed is adjusted 1/1635 or approximately 0.06%
Std: (70 MHz/32)/1635 = 1338 pps
Example: If the setting is changed by "+10" then:
(70 MHz/32)/(1635-10) =
(70 MHz/32)/(1625) = 1346 pps
2 FeedM:R2 DFU
[-30 to +30/0/1]
For every change of "1", speed is adjusted 1/1635 or approximately 0.06%
Std: (70 MHz/32)/1635 = 1338 pps
Example: If the setting is changed by "+10" then:
(70 MHz/32)/(1635-10) =
(70 MHz/32)/(1625) = 1346 pps
5 FeedM:CutS DFU
[-30 to +30/0/1]
For every change of "1", speed is adjusted 1/1063 or approximately 0.094%
Std: (19.6608 MHz/32)/1063 = 578 pps
Example: If the setting is changed by "+10" then:
(19.6608 MHz/32)/(1063-10) =
(19.6608 MHz/32)/(1053) = 583 pps
6 Main Motor DFU
[-80 to +80/0/1]
For every change of "1", speed is adjusted 1/2485 or approximately 0.035%.
Std: (19.6608 MHz/8)/2485 = 988.07 pps
Example: If the setting changed by "+10" then:
(19.6608 MHz/8)/(2485-10) =
(19.6608 MHz/8)/(2475) = 992.9 pps
7 Fusing Motor DFU
[-100 to +100/7/1
Feed Motor: 1st Roll
Feed Motor: 2nd Roll
Feed Motor : Cut Paper Tray
SP1-xxx Feed