5. Service Tables
1943
PreFB:HT:SP
This SP sets the high temperature used by pressure roller feedback temperature control for
Custom paper.
Note: Modes "1" to "5" below refer to the paper type and thickness settings selected in User
Tools (see "Paper Thickness Default Selection" in this section).
1 Plain: Mode1
2 Plain: Mode2
3 Plain: Mode3
4 Plain: Mode4
5 Plain: Mode5
5
1944
PreFB:LT:SP
This SP sets the low temperature used by pressure roller feedback temperature control for
Custom paper.
Note: Modes "1" to "5" below refer to the paper type and thickness settings selected in User
Tools (see "Paper Thickness Default Selection" in this section).
1 Plain: Mode1
2 Plain: Mode2
3 Plain: Mode3
4 Plain: Mode4
5 Plain: Mode5
1945
LLvl Set
These SP's define the Length Levels for the following SP codes:
• SP1946 Press FB Stop: Target Temp Diff.
• SP1947 Press FB Stop: Time Period
1 Level 1
2 Level 2
3 Level 3
272
Press Feedback Temperature: High Temperature: Special
o
[0 to 50/0/5
C]
o
[0 to 50/20/5
C]
o
[0 to 50/0/5
C]
Press Feedback Temperature: Low Temperature: Special
o
[0 to 50/0/5
C]
o
[0 to 50/10/5
C]
o
[0 to 50/5/5
C]
Length Level Setting
[1000 to 15000/1300/1 mm]
[1000 to 15000/3700/1 mm]
[1000 to 15000/61001 mm]