3. Replacement and Adjustment
Transfer Corona, Separation Corona Wires
3
1. Remove:
• Side covers (See p.112 "Side Covers")
2. Transfer unit [A] ( x 2, x 2)
Reinstallation
• At each end of the unit, make sure that the tabs [B] are fully engaged with the studs [C].
• When the tabs are engaged correctly, the caps on the end are fully level.