Sp6-Xxx Peripherals - Ricoh Neptune-P1 Service Manual

Table of Contents

Advertisement

5. Service Tables

SP6-xxx Peripherals

6117
FU Input Chk
This SP retrieves the SP settings of each bit within 0.5 sec., collects the data into 1-byte, then
sends it to the controller. However, undefined sensor information on the Folder unit side is set
to "0" without checking the Folder unit.
• If there is no response from the Folder FD within the prescribed time after it is checked, the
1-byte data (sensor information) is set to "0".
• The requests for engine information stop after this SP screen is closed.
1 Fan Folder 1
5
Bit
Input
7
Not used
6
Not used
5
Original width sensor
4
Not used
3
Entrance sensor
2
Not used
1
Exit JG sensor
0
Not used
2 Fan Folder 2
Bit
Input
7
Original width sensor: 24 in.
6
Original width sensor: 18 in.
5
Original width sensor: 12 in.
4
Original width sensor: 30 in.
3
Original width sensor: 841 mm/34 in.
2
Original width sensor: 594 mm/22 in.
334
Folder Input Check
(7) 0000 0000 (1)
Status
---
---
36 in.
---
0: No paper, 1: Paper present
---
0: No paper, 1: Paper present
---
Status
0: No paper, 1: Paper present
0: No paper, 1: Paper present
0: No paper, 1: Paper present
0: No paper, 1: Paper present
0: No paper, 1: Paper present
0: No paper, 1: Paper present

Advertisement