5. Service Tables
• However, for succeeding sheets where the time prescribed for feedback suspension is "0",
the "0" value is not overwritten, but feedback suspension control is maintained until
countdown for the multiple copies is finished.
1 LLvl1:Norm
2 LLvl2:Norm
3 LLvl3:Norm
4 LLvl4:Norm
5 LLvl5:Norm
11 LLvl1:Cold
12 LLvl2:Cold
5
13 LLvl3:Cold
14 LLvl4:Cold
15 LLvl5:Cold
16 LLvl0:Cold
Normally, pressure roller feedback control does not operate when the paper length is not
prescribed (length = 0). But if copying was started while feedback control was not operating,
during a cold start for example, then feedback control operates using the setting of this SP code.
[0 to 300/15/1 sec.]
17 LLvl0:False
The target hot roller temperature for a flying start is determined by SP1931. This SP determines
the time limit for the hot roller to reach that target hot roller temperature.
[0 to 300/20/1 sec.]
18 Stby:AftCold
This SP sets a time period that prohibits printing to begin even after the hot roller temperature
reaches its target temperature after a cold start. If a job is started during this time period
countdown, the countdown changes to the counts for-11 to -17 above.
[0 to 300/60/1 sec.]
1948
PreRol TTemp
This SP determines when inching starts.
274
Length Level 1: Normal
Length Level 2: Normal
Length Level 3: Normal
Length Level 4: Normal
Length Level 5: Normal
Length Level 1: Cold Start
Length Level 2: Cold Start
Length Level 3: Cold Start
Length Level 4: Cold Start
Length Level 5: Cold Start
Length Level 0: Cold Start
Length Level 0: False Start
Standby After Cold Start
Pressure Roller Inching Target Temperature
[0 to 300/15/1 sec.]
[0 to 300/30/1 sec.]
[0 to 300/45/1 sec.]
[0 to 300/60/1 sec.]
[0 to 300/80/1 sec.]
[0 to 300/20/1 sec.]
[0 to 300/35/1 sec.]
[0 to 300/50/1 sec.]
[0 to 300/70/1 sec.]
[0 to 300/100/1 sec.]