Ricoh Neptune-P1 Service Manual page 431

Table of Contents

Advertisement

6. Details
-11 to 15
1932-1 to 5
-6 to 10
-11 to 15
1934-1 to 5
-6 to 10
-11 to 15
1935-1 to -5
-6 to 10
-11 to 15
1941-1
6
1
1942-1 to 5*
1
1943-1 to 5*
1944-1 to -5
1948-1 to 5
-6 to 10
-11 to x15
1
*
SP1942, SP1943, SP1944 do not operate if they are set to "0".
Pressure Roller Temperature Feedback
The graph and descriptions below (Plain Paper, Mode 3 selected) show how the temperature of the hot
roller is controlled using the difference in the temperatures of the center and end of the pressure roller.
The temperature readings are fed back by the pressure roller thermistors (one at the end and one at the
center of the pressure roller). These difference between these readings are compared with the value set for
SP1941 (Press FB Ctrl Switch by Temp Diff).
430
120 to 220
Film
60 to 180
Plain
60 to 180
Translucent
60 to 180
Film
0 to 50
Plain
0 to 50
Translucent
0 to 50
Film
0 to 50
Plain
0 to 50
Translucent
0 to 50
Film
0 to 50
Plain
0 to 50
Plain
0 to 50
Plain
0 to 50
Plain
60 to 180
Plain
60 to 180
Translucent
60 to 180
Film
Difference between Center, End Temperatures
< SP1941 (20
195
190
100
85
130
100
60
60
20
15
20
20
20
20
20
25
20
20
20
20
0
0
0
0
0
0
100
65
130
100
60
60
o
C)
> SP1941 (20
185
185
175
60
60
60
60
60
60
60
60
60
25
20
20
20
20
20
20
20
20
30
20
20
20
20
20
20
20
20
20
5
15
0
20
20
0
10
5
0
60
60
60
60
60
60
60
60
60
o
C)

Advertisement