Sets the alarm to sound for the specified jam level (document misfeeds are not included).
[0 to 3 / 3 / 1 step]
0: Zero (Off)
1: Low (2.5K jams)
2: Medium (3K jams)
3: High (6K jams)
Error Alarm
5505
Sets the error alarm level. Japan only DFU
[000 to 255 / 001 / 100 copies per step]
5507
Supply Alarm DFU
1 Paper Size
Switches the control call on/off for the paper supply. DFU
0: Off, 1: On
0: No alarm.
1: Sets the alarm to sound for the specified number transfer sheets for each paper size
(A3, A4, B4, B5, DLT, LG, LT, HLT)
3 Toner
Switches the control call on/off for the toner end. DFU
0: Off, 1: On
If you select "1" the alarm will sound when the main machine detects toner end.
The "Interval nn" SP's below specify the paper control call interval for the referenced
paper sizes. DFU
[00250 to 10000 / 1000 / 1 Step]
97 Interval: 841mm
98 Interval: 594mm
99 Interval: 420mm
100 Interval: 297mm
101 Interval: 210mm
164 Interval: LG
165 Interval: Foolscap
166 Interval: LT
175 Interval: 12x18
225 Interval: 36inch
SP5-xxx Mode
5
297