2. Preventive Maintenance

PM Table

Key for the PM Table
A = Adjust, C = Clean, I = Inspect, L = Lubricate, R = Replace
• Units of measure in the PM Interval column: Metric: 1,000 meters, Feet: 1,000 feet

Main Machine (G180)

Description
Development
Developer (1,000 g)
Development Filter
Development Roller Gear
Development Lower Casing
Cleaning
Cleaning Blade
Cleaning Entrance Seal
Side Seals
Inside Cleaning Unit
Used Toner Bottle
Registration
Registration Rollers
Paper Registration Sensor
PM Interval
Q'ty
Metric
Feet
2
27.5
90.0
5.5
18.0
5.5
18.0
5.5
18.0
1
11.0
36.0
11.0
36.0
11.0
36.0
11.0
36.0
5.5
18.0
5.5
18.0
5.5
18.0
PM
Comments
R
Replace if necessary.
C
Dry cloth or vacuum cleaner
I
C
Dry
I/R
Replace if necessary.
C
Lens paper or dry cloth.
C
I
Dry cloth or vacuum cleaner
C
Empty used toner
C
Damp cloth
C
Blower brush