3. Replacement and Adjustment
Cassette Feed Motor, Cassette Open Sensor
3
1. Open the roll feeder drawer and remove the paper cassette unit.
2. Relay sensor plate, cassette end sensor plate [A] ( x 1 each)
3. Cassette open sensor [B] ( x 1, pinch release x 2)
4. Paper cassette feed assembly [C] ( x 6)
5. Paper cassette motor [D] ( x 2, x 1, x 2)
148