5. Service Tables
14 BpTr:OILEdge
15 BpFm:ILEdge
16 BpFm:OILEdge
17 CaILEdge
18 CaOILEdge
5
2801
Init Devr
This SP mixes the developer and initializes the ID sensor. Use this SP to mix the developer during
machine installation or after the developer has been replaced. The machine requires two packs
of developer. Two SP codes are provided for entering the lot numbers of both packages.
Note:
• Always enter the lot numbers with SP2801-2 and -3 before doing SP2801-1.
1 Initialize
2 Lot Number1
3 Lot Number2
2803
CWClean:Str
Do this SP to clean the charge corona wire. This SP also moves the cleaning pad to the home
position. The cleaning requires about 20 sec. to complete.
2804
CWClwan:Int
Sets the interval for charge corona wire cleaning.
Note: The wire is cleaned only when the hot roller temperature is below 50 °C (122°F).
[0 to 6/3/1 step]
0: None (no cleaning)
282
Bypass: Translucent:
Outside Image Leading
Edge
Bypass: Film: Image
Leading Edge
Bypass: Film: Outside
Image Leading Edge
Cassette: Image Leading
Edge
Cassette: Outside Image
Leading Edge
Initialize Developer
Developer Initial Setting:
Execute
Lot Number 1
Lot Number 2
Corona Wire: Cleaning Start
[0.0 to -66/ -15/0.1 mA]
[0.0 to -66/ -15/0.1 mA]
[0.0 to -66/ -15/0.1 mA]
[0.0 to -66/0/0.1 mA]
[0.0 to -66/0/0.1 mA]
Mixes developer and initializes the ID
sensor
Lot number of the 1st packet.
Lot number of the 2nd packet.
Corona Wire: Cleaning Interval