5. Service Tables
50 MFL:AdjFold
Use this SP to adjust fold length for short folds. The folds are done with motor timing only,
because the folded edges will not reach the front and rear fold sensors. The input of the fold
sensors is ignored and not used.
[-70.0 to +70.0/0.0/0.1]
51 MFL:File
This SP fine adjusts the calculated length of the file flap.
[-20 to +20/0/0.1]
61 MFL:Threshold
This SP adjusts the threshold variable that the machine uses to calculate when to do adjusted
folding.
5
[-70 to +70/0/0.1]
91 StdF Swtchg
This SP determines whether the lengths of the sections can be adjusted for folding standard
paper sizes.
[0 to 1/0/1]
0: Adjustment allowed
1: Adjustment not allowed
6965
CF: PFold Adj Not Used
6966
FF:Sel Fold
1 StdF Swtchg
This SP determines whether fixed pattern printing only is enabled when the Folder unit is online.
[0 to 1/0/1]
0: Disable
1: Enable fixed pattern only
6969
Bypass Set DFU
1 Destination
This sets the how the bypass feed sensors read paper sizes.
352
Margin Fold Length: Adjust Fold
Margin Fold Length: File
Margin Fold Length: Threshold
Regular Size Fold Switching
Pre-Fold Adjustment (Corner Folder)
Fan Folder Select Standard Folding
Bypass Feed Setting