Displays a number that describes the error code that was issued when either SP5816 204
or SP5816 207 was executed.
Cause
Illegal Modem Parameter
Operation Error, Incorrect
Setting
Error Caused by Response
from GW URL
Code
Meaning
-11001
Chat parameter error
-11002
Chat execution error
-11003
Unexpected error
Inquiry, registration attempted without
-12002
acquiring device status.
Attempted registration without execution of an
-12003
inquiry and no previous registration.
Attempted setting with illegal entries for
-12004
certification and ID2.
-12005
@Remove communication prohibited
Confirmation requested again after
-12006
confirmation completed.
Different numbers were used for registration
-12007
and confirmation.
Update certification failed because device
-120008
was in use.
Attempted dial up overseas without the correct
-2385
international prefix for the telephone number.
-2387
Not supported at the Service Center
-2389
Database out of service
-2390
Program out of service
-2391
Two registrations for same device
-2392
Parameter error
-2393
Basil not managed
-2394
Device not managed
-2395
Box ID for Basil is illegal
SP5-xxx Mode
5
313