Ricoh Neptune-P1 Service Manual page 321

Table of Contents

Advertisement

5. Service Tables
5682 message log where the
following are set:
5844
USB
1 Transfer Rate
Sets the speed for USB data transmission.
[Full Speed], [Auto Change]
2 Vendor ID
Sets the vendor ID:
Initial Setting: 0x05A Ricoh Company
[0x0000 to 0xFFFF/1] DFU
5
3 Product ID
Sets the product ID.
[0x0000 to 0xFFFF/1] DFU
4 Device Release No.
Sets the device release number of the BCD (binary coded decimal) display.
[0000 to 9999/1] DFU
Enter as a decimal number. NCS converts the number to hexadecimal number recognized as
the BCD.
Delivery Server Setting
5845
Provides items for delivery server settings.
3 Retry Interval
Determines the time interval between retries before the machine returns to standby after an
error occurs during an image transfer with the delivery scanner or SMTP server.
[60 to 900/300/1]
4 Number of Retries
Determines the number of retries before the machine returns to standby after an error occurs
during an image transfer with the delivery or SMTP server.
[0 to 99/3/1]
320
1: mm:ss:ms
0: mm:ss (time)

Advertisement

Table of Contents
loading

Table of Contents