Mitsubishi Electric MELSEC iQ-R16MTCPU Programming Manual page 444

Melsec iq-r series motion controller
Hide thumbs Also See for MELSEC iQ-R16MTCPU:
Table of Contents

Advertisement

No.
Name
SD280
Word device number
of points assigned
SD281
SD282
SD283
SD350
Accumulative power-
on time
SD351
SD360
Internal temperature
of Motion CPU
SD480
Motion CPU
operation cycle over
count
SD484
Fixed scan data
transmission section
over count
SD502
Servo amplifier
loading information
SD503
APPENDICES
442
Appendix 4 Special Registers
Data stored
Details
D number of points assigned
• The number of points of the device D currently set is stored as 32-bit
(L)
• The number of points assigned is stored even when the number of
D number of points assigned
(H)
W number of points
assigned (L)
W number of points
assigned (H)
Accumulative power-on time
The accumulative power-on time (mins) of the Motion CPU module is
(mins)
stored.
Internal temperature of
The internal temperature () of the Motion CPU module is stored.
Motion CPU ()
(When -12, "-12" is stored.)
0: Motion operation cycle
Stores the count for the motion operation process (including inter-module
over not occurrence
synchronization process) not completed within the motion operation
(Normal)
cycle.
1 to 65535: Operation cycle
After exceeding 65535 the count returns to 0 and counts again.
over cumulative count
The counts are stored regardless of the "CPU module operation setting
at error detected" RAS setting.
This counter is valid even is inter-module synchronization is not used.
0: Fixed scan data
Stores the count for the motion operation process not completed by the
transmission section over
fixed-cycle data transmission set in the Multiple CPU synchronous cycle.
not occurrence (Normal)
After exceeding 65535 the count returns to 0 and counts again. The
1 to 65535: Fixed scan data
counts are stored regardless of the "CPU module operation setting at
transmission section over
error detected" RAS setting.
cumulative count
This counter is valid even is inter-module synchronization is not used.
Servo amplifier loading
• When power supply of Multiple CPU system is turned ON or reset,
information
SD502
SD503
• The device is reset when communication with the servo amplifier is
• The loading status for axes that change between non-loaded/loaded
• The loaded/non-loaded status of a servo amplifier are described
Status
Loaded
Non-
loaded
• The servo network setting and servo amplifier loading status are
Servo network setting
Used(Axis No. settings)
Not used
data.
points assigned to D is 32K points or less.
servo amplifier loading information is checked and the result is stored
as bit data.
b15
to
b12
b11
to
b8
Axis 16 to Axis 13
Axis 12 to Axis 9
Axis 32 to Axis 29
Axis 28 to Axis 25
suspended.
after power supply ON are also stored.
below.
Details
The servo amplifier is in a normal state (communication with
the servo amplifier can be performed).
Servo amplifier is not loaded. The servo amplifier control
circuit power supply is turned OFF. Because of a failure
with the connection cable, communication with the servo
amplifier cannot be performed.
shown below.
b7
to
b4
b3
to
b0
Axis 8 to Axis 5
Axis 4 to Axis 1
Axis 24 to Axis 21
Axis 20 to Axis 17
0: Non-loaded
1: Loaded
Servo amplifier
Loaded
Non-loaded
1 is stored
0 is stored
0 is stored
0 is stored
Set by
(setting
timing)
S (Initial process)
S (Main process)
S (Status
change)
S (Operation
cycle)