Basic setting (parameter No. 1)
The basic setting is shown below.
Item
Operation cycle setting
Forced stop input setting
File transmission setting during
booting
Machine control setting
Low speed operation cycle
magnification setting
G-code control setting
Servo network setting (parameter No. 2)
Servo network setting is shown below.
Item
I/F module type
I/F module start I/O No.
I/F module Channel No.
Servo network type
Station No.
Axis No./RIO axis No.
Vendor ID
Type code
Servo parameter setting
information
Operation cycle selection
*1 n=the placing No. (1 to 32) where a servo amplifier is connected from the start of a line.
4 AUXILIARY AND APPLIED FUNCTIONS
132
4.10 Parameter Change Function
Parameter
Parameter ID
change
Line No.
Column No.
(SD845)
(SD844)
1
1
2
4
5
6
7
Parameter
Parameter ID
change
Line No.
Column No.
(SD845)
(SD844)
1
1
2
3
4
*1
n+1
1
2
3
4
6
11
Size
Initial
Setting range
(Word)
value
2
0
H0000: Default value
H0010: 0.222ms
H0020: 0.444ms
H0040: 0.888ms
H0080: 1.777ms
H0100: 3.555ms
H0200: 7.111ms
0
2
0
0:
Standard ROM write permission/read
protection
1:
Standard ROM write protection/read
protection
2:
Standard ROM write protection/read
permission
3:
Standard ROM write permission/read
permission
256: Boot operation file invalid
0
2
0
0: Not used
2: 2 times
4: 4 times
8: 8 times
1
0
0: Not used
1: Use line 1 only
2: Use line 1 and line 2
Size
Initial
Setting range
(Word)
value
0
0
2
0
0: Line 1
1: Line 2
2
0
0: SSCNET
1: SSCNET/H
2
0
0:
No setting axis
1 to 64:Station No.
2
0
1 to 64: Axis No.
601 to 608: RIO axis No.
2
0000H
H0000 to HFFFF
2
0000H
H0000 to HFFFF
2
0
2
0
0: Operation cycle
1: Low speed operation cycle