Mitsubishi Electric MELSEC iQ-R16MTCPU Programming Manual page 434

Melsec iq-r series motion controller
Hide thumbs Also See for MELSEC iQ-R16MTCPU:
Table of Contents

Advertisement

No.
Name
SD10
Self-diagnostic error
code
SD11
SD12
SD13
SD14
SD15
SD16
SD17
SD18
SD19
SD20
SD21
SD22
SD23
SD24
SD25
SD53
AC/DC DOWN
detection
SD61
I/O module verify
error module number
SD80
Detailed information
1 information
category
APPENDICES
432
Appendix 4 Special Registers
Data stored
Details
Self-diagnostic error code 1
The maximum of 16 types of error codes are stored into SD10 onwards
when the diagnostics detects an error.
Self-diagnostic error code 2
(The same error code as one already stored in SD10 onwards is not
Self-diagnostic error code 3
stored). The 17th error code onwards are not stored. Also error codes
are not stored when 16 types of error codes have already been stored
Self-diagnostic error code 4
into SD10 to SD25.
Self-diagnostic error code 5
Self-diagnostic error code 6
Self-diagnostic error code 7
Self-diagnostic error code 8
Self-diagnostic error code 9
Self-diagnostic error code
10
Self-diagnostic error code 11
Self-diagnostic error code
12
Self-diagnostic error code
13
Self-diagnostic error code
14
Self-diagnostic error code
15
Self-diagnostic error code
16
Number of times for AC/DC
• Every time the input voltage fails to or below (85[%] AC power/65[%]
DOWN detection
• The counter repeats a 0 to 65535 to 0 pattern.
I/O module verify error
The lowest I/O number of the module which has an error detected by the
module number
I/O module verification is stored.
Detailed information 1
• Detailed information 1 information category code is stored.
information category code
b15
• The following codes are stored into the information category code.
0: N/A
1: Program position information
2: Drive and file information
4: Parameter information
5: System configuration information
6: Number of times information
7: Time information
129: G-code control information
131: Machine control information
135: Add-on function information
141: Servo error/error at communication failure
142: Axis control error
143: Motion SFC program
DC power) the rating during calculation of the Motion CPU module, the
value is incremented by 1 and stored in BIN code.
to
b8 b7
Not used (fixed to 0)
Information block code
Set by
(setting
timing)
S (Error)
to
b0

Hide quick links: