■Analog input module
*1
Item
Basic
Range switching
Input range setting
setting
function
Operation mode
Operation mode setting
setting function
A/D conversion
A/D conversion enable/disable
enable/disable
setting
setting function
A/D conversion
Average processing setting
method
Time average/Count average/
Moving average/Primary delay
filter constant setting
LPF pass band edge frequency
HPF pass band edge frequency
BPF pass band edge frequency
(low)
BPF pass band edge frequency
(high)
Attenuation band width
*2
Setting range
4 to 20mA/0 to 20mA/1 to 5V/0 to 5V/-10V to 10V/
0 to 10V/4 to 20mA (Extend)/1 to 5V (Extend)/
User range setting
Normal mode(A/D conversion)/Normal mode(low speed:
20s/CH)/Normal mode(medium speed: 10s/CH)/
Simultaneous conversion mode(5s/4CH)/Offset/gain
setting mode
A/D conversion enable/A/D conversion disable
Sampling processing/Time average/Count average/Moving
average/Primary delay filter/Low pass filter/High pass filter/
Band pass filter
Time average: 1 to 5000ms
Count average: 4 to 62500 times
Moving average: 2 to 1000 times
Primary delay filter: 1 to 500 times
Low pass filter: 0 to 46700Hz
High pass filter: 171 to 48000Hz
Band pass filter: 171 to 46699Hz
Band pass filter: 172 to 46700Hz
Low pass filter: 170 to 48000Hz
High pass filter: 170 to 47999Hz
Band pass filter: 170 to 15999Hz
Default value
*3
*3
*3
Sampling processing