Mitsubishi Electric MELSEC iQ-R16MTCPU Programming Manual page 410

Melsec iq-r series motion controller
Hide thumbs Also See for MELSEC iQ-R16MTCPU:
Table of Contents

Advertisement

Error
Error name
code
3A4AH
UGn.m read error
3A4BH
U\HGn.m read error
3A54H
SM(n) read error
3A55H
X(n) read error
3A56H
Y(n) read error
3A57H
M(n) read error
3A58H
B(n) read error
3A59H
F(n) read error
3A5AH
SD(n).m Read Error
3A5BH
D(n).m Read Error
3A5CH
W(n).m Read Error
3A5DH
#(n).m Read Error
3A60H
16-bit batch Xn read error
3A61H
32-bit batch Xn read error
3A62H
16-bit batch Yn read error
3A63H
32-bit batch Yn read error
APPENDICES
408
Appendix 1 Error Codes
Error details and cause
The directly specified device No. is outside the range.
The directly specified device No. is outside the range.
The indirectly specified device No. is outside the range.
The indirectly specified device No. is outside the range.
The indirectly specified device No. is outside the range.
The indirectly specified device No. is outside the range.
The indirectly specified device No. is outside the range.
The indirectly specified device No. is outside the range.
The indirectly specified device No. is outside the range.
The indirectly specified device No. is outside the range.
The indirectly specified device No. is outside the range.
The indirectly specified device No. is outside the range.
The directly specified device No. is outside the range.
The directly specified device No. is outside the range.
The directly specified device No. is outside the range.
The directly specified device No. is outside the range.
Corrective action
• Correct the program so that the device No. which
directly specifies is proper.
• Correct the program so that the device No. which
directly specifies is proper.
• Correct the program so that the device No. which
indirectly specifies is proper.
• Correct the program so that the device No. which
indirectly specifies is proper.
• Correct the program so that the device No. which
indirectly specifies is proper.
• Correct the program so that the device No. which
indirectly specifies is proper.
• Set the device range according to the device number/
latch setting of relation setting of CPU parameter within
the valid range.
• Correct the program so that the device No. which
indirectly specifies is proper.
• Set the device range according to the device number/
latch setting of relation setting of CPU parameter within
the valid range.
• Correct the program so that the device No. which
indirectly specifies is proper.
• Set the device range according to the device number/
latch setting of relation setting of CPU parameter within
the valid range.
• Correct the program so that the device No. which
indirectly specifies is proper.
• Set the device range according to the device number/
latch setting of relation setting of CPU parameter within
the valid range.
• Correct the program so that the device No. which
indirectly specifies is proper.
• Set the device range according to the device number/
latch setting of relation setting of CPU parameter within
the valid range.
• Correct the program so that the device No. which
indirectly specifies is proper.
• Set the device range according to the device number/
latch setting of relation setting of CPU parameter within
the valid range.
• Correct the program so that the device No. which
indirectly specifies is proper.
• Set the device range according to the device number/
latch setting of relation setting of CPU parameter within
the valid range.
• Correct the program so that the device No. which
directly specifies is proper.
• Set the device range according to the device number/
latch setting of relation setting of CPU parameter within
the valid range.
• Correct the program so that the device No. which
directly specifies is proper.
• Set the device range according to the device number/
latch setting of relation setting of CPU parameter within
the valid range.
• Correct the program so that the device No. which
directly specifies is proper.
• Set the device range according to the device number/
latch setting of relation setting of CPU parameter within
the valid range.
• Correct the program so that the device No. which
directly specifies is proper.
• Set the device range according to the device number/
latch setting of relation setting of CPU parameter within
the valid range.

Hide quick links: