Error
Error name
code
3919H
MVPST execution error
391AH
MVLOAD execution error
391BH
MVTRG execution error
391CH
MVIN execution error
391DH
MVFIN execution error
391EH
MVCLOSE execution error
391FH
MVCOM execution error
3920H
SET execution error
3921H
RST execution error
3922H
SET= execution error
3923H
RST= execution error
3924H
DOUT execution error
3925H
DIN execution error
3926H
OUT= execution error
392EH
FOR (assign) execution
error
3930H
Bit opposite
(complemented) execution
error
3931H
Bit AND execution error
3932H
Bit OR execution error
3933H
Bit XOR execution error
3934H
Bit right-shifted execution
error
3935H
Bit left-shifted execution
error
3940H
NOT/OFF execution error
3941H
AND execution error
APPENDICES
402
Appendix 1 Error Codes
Error details and cause
Internal processing error occurred when MVPST is
executing.
Internal processing error occurred when MVLOAD is
executing.
Internal processing error occurred when MVTRG is
executing.
Internal processing error occurred when MVIN is
executing.
Internal processing error occurred when MVFIN is
executing.
Internal processing error occurred when MVCLOSE is
executing.
Internal processing error occurred when MVCOM is
executing.
The device number which indirectly specifies (D) is illegal.
The device number which indirectly specifies (D) is illegal.
The device number which indirectly specifies (D) is illegal.
The device number which indirectly specifies (D) is illegal.
The device number which indirectly specifies (D) is illegal.
The device number which indirectly specifies (D) is illegal.
The device number which indirectly specifies (D) is illegal.
Internal processing error occurred when FOR
(assignment) is executing.
Internal processing error occurred when bit which is in a
value is flipped to its opposite setting (complemented) is
executing.
Internal processing error occurred when bit AND is
executing.
Internal processing error occurred when bit OR is
executing.
Internal processing error occurred when bit XOR is
executing.
Internal processing error occurred when bit right-shifted is
executing.
• Internal processing error occurred when bit left-shifted
is executing.
Internal processing error occurred when NOT/OFF is
executing.
Internal processing error occurred when AND is
executing.
Corrective action
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
Correct the program so that the device number which
indirectly specifies (D) is proper.
Correct the program so that the device number which
indirectly specifies (D) is proper.
Correct the program so that the device number which
indirectly specifies (D) is proper.
Correct the program so that the device number which
indirectly specifies (D) is proper.
Correct the program so that the device number which
indirectly specifies (D) is proper.
Correct the program so that the device number which
indirectly specifies (D) is proper.
Correct the program so that the device number which
indirectly specifies (D) is proper.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.