3903H
BMOV execution error
3904H
TIME execution error
3905H
FMOV execution error
3908H
CHGV execution error
390AH
CHGP execution error
390BH
CHGT execution error
390CH
CHGVS execution error
390DH
MCNST executing error
3910H
Assign (=) execution error
3911H
Addition (+) execution
error
3912H
Subtraction (-) execution
error
3913H
Multiplication (*) execution
error
3914H
Division (/) execution error
3915H
Remainder (%) execution
error
3917H
MVOUT execution error
3918H
MVOPEN execution error
Error details and cause
• (S) to (S)+(n-1) is outside the device range.
• (S) is a bit device and its device number is not a multiple
of 16.
• (D) to (D)+(n-1) is outside the device range.
• (D) is a bit device and its device number is not a
multiple of 16.
• (n) is outside the range of 0 to 1000000000.
• The combination of (S) and (D) is not correct.
The data of (S) is outside the range of 0 to 2147483647.
• (D) to (D)+(n-1) is outside the range of the device.
• (n) is outside the range of 0 to 1000000000.
• (D) is the CPU buffer memory other than self CPU or
the module access device of the module other than self
CPU management.
The specified axis number of (S1) is outside the range.
• The specified axis number of (S1) is outside the range.
• (S2) is outside the range of 0 to 1.
• The device number of (S3) is an odd number.
• (S3) to ((S3)+7) is outside the range of device.
The specified axis number of (S1) is outside the range.
The specified axis number of (S1) is outside the range.
Error occurred during machine program operation start
request.
• The (S) data is outside the range of the data type of (D).
• The device number which indirectly specifies (D) is
illegal.
Internal processing error occurred when addition (+) is
executing.
Internal processing error occurred when subtraction (-) is
executing.
Internal processing error occurred when multiplication (*)
is executing.
The divisor is 0.
The divisor is 0.
Internal processing error occurred when MVOUT is
executing.
Internal processing error occurred when MVOPEN is
executing.
Corrective action
• Change (S) or (n) so that the block transfer range is
within the device range.
• When (S) is a bit device, correct the program so that the
device number to be multiple of 16.
• Change (D) or (n) so that the block transfer range is
within the device range.
• When (D) is a bit device, correct the program so that the
device number to be multiple of 16.
• Correct the program so that (n) is within the range of 0
to 1000000000.
• Correct the program so that the combination of (S) and
(D) is correct.
Correct the program so that the data of (S) is within the
range of 0 to 2147483647.
• Change (D) or (n) so that the block transfer range is
within the device range.
• Correct the program so that (n) is within the range of 0
to 1000000000.
• Correct the program so that (D) is the CPU buffer
memory of self CPU or the module access device of the
module of self CPU management.
Correct the specified axis number of (S1) to be within the
range.
• Correct the specified axis number of (S1) to be within
the range.
• Correct the program so that the (S2) is within the range
of 0 to 1.
• Correct the program so that the (S3) is an even number
device.
• Correct the program so that (S3) to ((S3)+7) is within
the range of device.
Correct the specified axis number of (S1) to be within the
range.
Correct the specified axis number of (S1) to be within the
range.
• Check the setting of machine program operation.
• Check the error content in detailed code and process
accordingly. (For the detail code, refer to MELSEC
iQ-R Motion Controller Programming Manual (Program
Design).)
• Correct the program so that the data of (S) is within the
range of the data (D) type.
• Correct the program so that to the device number which
indirectly specifies (D) is proper.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
Correct the program so that the divisor is not 0.
Correct the program so that the divisor is not 0.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.