When the stop command turns ON during acceleration processing of advanced S-curve acceleration/
deceleration, in order to maintain smoothness of acceleration, the speed will continue to increase until
acceleration reaches zero.
Use the rapid stop command if an increase in speed is not desired.
■Rapid stop processing
• Rapid stop during acceleration
When the rapid stop command turns ON during acceleration, acceleration immediately goes to zero, and rapid stop
deceleration processing is executed. (Deceleration is abrupt.)
Speed
Setting speed
Control during rapid
stop command OFF
0
Acceleration
AmaxA
0
EmaxA
[Rq.1141] Rapid stop command
OFF
(R: M34481+32n/Q: M3201+20n)
• Rapid stop during deceleration
When the rapid stop command turns ON during deceleration, the negative acceleration is decreased, and the rapid stop
deceleration processing is executed.
Speed
Setting speed
0
Acceleration
0
DmaxA
EmaxA
[Rq.1141] Rapid stop command
OFF
(R: M34481+32n/Q: M3201+20n)
Rapid stop
processing
Control during rapid
stop command OFF
ON
Control during rapid
stop command OFF
Rapid stop
processing
Control during rapid
stop command OFF
ON
Time
Time
Time
Time
3 PARAMETERS FOR POSITIONING CONTROL
3.13 Parameter Block