Ex.
When the current stop address is (1000, 2000, 1000), and the specified address is (4000, 8000, 4000).
Positioning address
(4000, 8000, 4000)
Forward direction
8000
Forward
direction
2000
4000
1000
0
1000
Home position
■Control using INC-3 (Incremental data method)
• Positioning control from the current stop address to the position which combined travel direction and travel value specified
with each axis is executed.
• The travel direction for each axis is set by the sign (+/ -) of the travel value for each axis, as follows:
Travel direction
Positive
Negative
Forward direction
Forward
direction
Z
1
Z-axis
travel
value
Reverse
direction
0
Reverse
direction
Ex.
X-axis travel value is 10000, Y-axis travel value is 5000 and Z-axis value is 6000.
Forward direction
Forward direction
5000
6000
Z-axis travel
value (6000)
0
Home position
X-axis, Y-axis and Z-axis linear
interpolation operation
Current stop address
(1000, 2000, 1000)
Forward direction
4000
Description
Positioning control to forward direction (Address increase direction)
Positioning control to reverse direction (Address decrease direction)
*:
Y
1
Y-axis travel
value
X
1
Current stop position
X-axis travel
value
Reverse
direction
Stop position after
positioning
(12300, 6300, 8000)
Current stop address
(2300, 1300, 2000)
5000
10000
X-axis travel value (10000)
Indicates setting data.
Forward
direction
Positioning
operation
Y-axis travel
value (5000)
Forward
direction
5.4 3 Axes Linear Interpolation Control
5 POSITIONING CONTROL
5
277