[St.1046] Operation cycle over flag (R: M30054/Q: M2054)
This flag turns on when the time concerning motion operation exceeds the "Motion setting operation cycle (SD523)". Refer to
the following for details.
MELSEC iQ-R Motion controller Programming Manual (Common)
Perform the following operation, in making it turn off.
• Turn the Multiple CPU system power supply ONOFF
• Reset the Multiple CPU system
• Reset using the user program
■Countermeasures for operation cycle over
• Change the operation cycle to a larger value in the [Motion CPU Common Parameter]  [Basic Setting]  "Operation
Cycle".
• Reduce the number of executions of event task and NMI task instructions in the Motion SFC program.
[St.1040] Start accept flag (R: M30080+n/Q: M2001+n)
• This flag turns on when axis control is started by the servo program or the command signals. The start accept flag of the
controlled axis turns ON.
• The start accept flag turns ON when the following control is being executed.
• Servo program
• Direct positioning control by the Motion dedicated PLC instruction (M(P).SVSTD/D(P).SVSTD)
• JOG operation
• Manual pulse generator operation
• Speed-torque control
• Synchronous control operation (output axis)
• Current value change
• Pressure control
• Machine program operation
• Machine JOG operation
• G-code control
• The state of the start accept flag during positioning control by servo program is shown below.
Servo program start
[St.1040] Start accept flag
OFF
(R: M30080+n/Q: M2001+n)
[St.1061] Positioning complete
OFF
(R: M32401+32n/Q: M2401+20n)
[St.1060] Positioning start complete
OFF
(R: M32400+32n/Q: M2400+20n)
• The state of the start accept flag of a current value change by the CHGA instruction of servo program or by the Motion
dedicated PLC instruction (M(P).CHGA/D(P).CHGA) is shown below.
CHGA instruction
OFF
[St.1040] Start accept flag
(R: M30080+n/Q: M2001+n)
Normal positioning completion
V
Dwell time
Positioning
completion
ON
ON
ON
ON
Current value changing
processing
t
Servo program start
[St.1040] Start accept flag
(R: M30080+n/Q: M2001+n)
[St.1061] Positioning complete
(R: M32401+32n/Q: M2401+20n)
[St.1060] Positioning start complete
(R: M32400+32n/Q: M2400+20n)
Turns off at the completion of
current value change.
2 POSITIONING DEDICATED SIGNALS
Positioning stop during control
V
t
Positioning
Positioning
stop
start
completion
ON
OFF
OFF
ON
OFF
2.1 Internal Relays