Mitsubishi Electric MELSEC iQ-R16MTCPU Programming Manual page 366

Melsec iq-r series, positioning control
Hide thumbs Also See for MELSEC iQ-R16MTCPU:
Table of Contents

Advertisement

• Sequence program
Sequence program for FIN signal wait function is shown below.
X0
0
M0
11
M2419
14
M2419
26
28
*1 The automatic refresh setting example for FIN signal wait function is shown below.
5 POSITIONING CONTROL
364
5.17 Continuous Trajectory Control
DP.SFCS H3E1
MOVP
DP.DDRD
H3E1
D50
"D13"
K110
M0
D0
Motion SFC program start request
K1
D51
Substitutes 1 for D51 after program start.
Reads data of D13 for Multiple CPU
D1
M2
system No.2 by turning M2419 on,
and stores in the data area D1 of self
SET
M3219
M3219 is set
RST
M3219
Resets M3219 by turning M2419 OFF.
END
*: Details of D1 is used as control.