Basler BE1-11g Instruction Manual page 670

Generator protection system
Hide thumbs Also See for BE1-11g:
Table of Contents

Advertisement

658
IEC 60255-5:
Electrical Insulation Tests for Electrical Relays. Dielectric Test and Impulse Test
IEC 60255-6:
Electrical Relays - Measuring Relays and Protection Equipment
IEC 60255-21-1: Vibration, Shock, Bump, and Seismic Tests on Measuring Relays and Protective
Equipment (Section 1 - Vibration Test - Sinusoidal). Class 1
IEC 60255-21-2: Vibration, Shock, Bump, and Seismic Tests on Measuring Relays and Protective
Equipment (Section 2 - Shock and Bump Test - Sinusoidal). Class 1
IEEE C37.90.1: Surge Withstand Capability (SWC) Tests for Relays and Relay Systems Associated
with Electric Power Apparatus
IEEE C37.90.2: Withstand Capability of Relay Systems to Radiated Electromagnetic Interference from
Transceivers
UL Approval
"cURus" recognized to UL Standard 508 & CSA Standard C22.2 No.14
"cURus" recognized per Standard ISA 12.12.01, Electrical Equipment for Use in Class I and II, Division
2, and Class III Division 1 and 2 Hazardous (Classified) Locations. For use in Class I, Division 2,
Groups A, B, C, D, Temperature Code - T4 & CSA C22.2 No. 213-M1987 (Reaffirmed 1999). For use in
Class I, Division 2 Hazardous locations.
CSA Certification
CSA certified to Standard C22.2 No.14.
EU Compliance
This product has been evaluated and complies with the requirements set forth by the EU legislation.
LVD 2014/35/EU
EMC 2014/30/EU
Harmonized Standards used for evaluation:
EN 50178:1997 - Electronic Equipment for use in Power Installations
EN 61000-6-4:2001 - Electromagnetic Compatibility (EMC), Generic Standards, Emission
Standard for Industrial Environments
EN 61000-6-2:2001 - Electromagnetic Compatibility (EMC), Generic Standards, Immunity for
Industrial Environments
EN 61000-4-2: Electrostatic Discharge Immunity
EN 61000-4-3: Radiated, Radio-Frequency, Electromagnetic Field Immunity
EN 61000-4-4: EFT Immunity
EN 61000-4-5: Surge Immunity
EN 61000-4-6: Conducted Immunity
EN 61000-4-8: Power Frequency Magnetic Field Immunity
EN 61000-4-11: Voltage Dips and Interrupts
HALT (Highly Accelerated Life Testing)
Basler Electric uses HALT to prove that our products will provide the user with many years of reliable
service. HALT subjects the device to extremes in temperature, shock, and vibration to simulate years of
operation, but in a much shorter period span. HALT allows Basler Electric to evaluate all possible design
elements that will add to the life of this device. As an example of some of the extreme testing conditions,
the RTD module was subjected to temperature extremes of –80°C to +130°C, vibration extremes of 5 to
45 G at +20°C, and temperature/vibration extremes of 45 G over a temperature range of –60°C to
+110°C. Combined temperature and vibration testing at these extremes proves that the RTD module is
expected to provide long-term operation in a rugged environment. Note that the vibration and temperature
RTD Module
9424200994 Rev U
BE1-11g