Summary of Contents for Basler BE1-11f

  • Page 1 QUICK START GUIDE BE1-11 Protection Systems Publication: 9424200772 Revision: D May-17...
  • Page 3 Programming BESTlogic™Plus programmable logic For complete information on a specific BE1-11 Protection System, refer to one of the following instruction manuals: • BE1-11f, Feeder Protection System, Publication 9424200990 • BE1-11g, Generator Protection System, Publication 9424200994 • BE1-11i, Intertie Protection System, Publication 9424200993 •...
  • Page 4 The availability and design of all features and options are subject to modification without notice. Over time, improvements and revisions may be made to this publication. Before performing any of the following procedures, contact Basler Electric for the latest revision of this manual.
  • Page 5: Table Of Contents

    9424200772 Rev D Contents Quick Start Guide ............................1 Maintenance .............................. 1 Storage ..............................1 Install BESTCOMSPlus® Software ......................1 Power Up and Activate the BE1-11 Plug-In ....................2 USB Connection ............................ 2 Apply Operating Power .......................... 2 Start BESTCOMSPlus® and Activate BE1-11 Plugin ................4 Programming the BE1-11 ..........................
  • Page 6 9424200772 Rev D Contents BE1-11...
  • Page 7: Quick Start Guide

    If there is evidence of shipping damage, file a claim with the carrier, and notify the Basler Electric Regional Sales Office, your sales representative, or a sales representative at Basler Electric, Highland, Illinois.
  • Page 8: Power Up And Activate The Be1-11 Plug-In

    When BESTCOMSPlus installation is complete, a Basler Electric folder is added to the Windows programs menu. This folder is accessed by clicking the Windows Start button and then accessing the Basler Electric folder in the Programs menu. The Basler Electric folder contains an icon that starts BESTCOMSPlus when clicked.
  • Page 9 BE1-11 in a J type case with standard I/O option. Figure 3 shows the rear terminals of the BE1-11 in an H or P type case (BE1-11f, BE1-11i, and BE1-11g only). Apply operating power consistent with the nominal power supply values listed on the front-panel label. Wait until the boot sequence is complete.
  • Page 10: Start Bestcomsplus® And Activate Be1-11 Plugin

    Highland, Illinois USA (618) 654-2341 P0069-28 Figure 3. PWR Rear Terminals (H or P Type Case) (BE1-11f, BE1-11i, and BE1-11g only) Start BESTCOMSPlus® and Activate BE1-11 Plugin To start BESTCOMSPlus, click the Start button, point to Programs, Basler Electric, and then click the BESTCOMSPlus icon.
  • Page 11 9424200772 Rev D Figure 5. BESTCOMSPlus Splash Screen The BESTCOMSPlus platform window opens. Select New Connection from the Communication pull-down menu and select BE1-11. See Figure 6. The BE1-11 plugin is activated automatically after connecting to a BE1-11. Figure 6. Communication Pull-Down Menu The BE1-11 Connection screen shown in Figure 7 appears.
  • Page 12: Programming The Be1-11

    Figure 7. BE1-11 Connection Screen Programming the BE1-11 This section contains an introduction to BESTCOMSPlus, explains summary screens, and gives an example of settings elements and programming logic for the BE1-11f Feeder Protection System. Other applications are similar. Introduction to BESTCOMSPlus®...
  • Page 13: Summary Screens

    9424200772 Rev D Figure 8. BESTCOMSPlus Typical User Interface Components Click the View drop-down button to switch between the Settings Explorer and Metering Explorer or split the view between both. The Settings Info Panel displays settings ranges. A workspace can be opened, saved, or set as default.
  • Page 14: Programming Example

    9424200772 Rev D Figure 10. System Summary Screen Programming Example Changing default logic is sometimes required to match the protection requirements of the system. Additionally, elements must be enabled and operating settings set. This example demonstrates how to configure typical nominal settings and program the 50-3 instantaneous overcurrent element. System nominal quantities are set to 69.3 volts and 3.6 amps.
  • Page 15 9424200772 Rev D Figure 11. Power System Screen Figure 12. Instantaneous Overcurrent (50-3) Screen Step 9: In the Settings Explorer, click BESTlogicPlus Programmable Logic to open the logic diagram. Click the Logic Page 1 tab. See Figure 13. Examine the 50-3 element. The Logic 0 connected to the Block input indicates that the 50-3 element is never blocked.
  • Page 16 9424200772 Rev D Figure 13. BESTlogicPlus Logic Page 1 Figure 14. BESTlogicPlus Logic Page 2 Quick Start Guide BE1-11...
  • Page 17 9424200772 Rev D Figure 15. BESTlogicPlus Logic Page 3 Step 10: In this step, the Pickup output of the 50-3 element is connected to Output 4. When the Pickup output of the 50-3 element is true, the label of Output 4 is displayed in the fault report and/or sequence of events report.
  • Page 18 9424200772 Rev D Figure 17. BESTlogicPlus Programming User Alarm 1 Step 12: Click the Save button to save the logic to BESTCOMSPlus memory for later inclusion in the settings file. See Figure 18. Figure 18. BESTlogicPlus Toolbar Step 13: In the Settings Explorer, expand Programmable Outputs, Contact Outputs, and name Output #4 (50-3 Pickup) as shown in Figure 19.
  • Page 19 9424200772 Rev D Figure 20. User Programmable Alarms Screen Step 15: Figure 21 shows the user-defined labels of OUT4 and USERALM1 that were named in Step 13 and Step 14. Step 16: Select Save from the File pull-down menu to save your new settings file. Step 17: To make your new settings active in the BE1-11, select Upload Settings and Logic to Device from the Communication pull-down menu.
  • Page 20 9424200772 Rev D Quick Start Guide BE1-11...
  • Page 21: Revision History

    9424200772 Rev D Revision History Table 2 provides a historical summary of the changes made to this quick start guide. Revisions are listed in chronological order. Table 2. Quick Start Guide Revision History Quick Start Guide Change Revision and Date •...
  • Page 22 9424200772 Rev D Revision History BE1-11...
  • Page 24 Highland IL 62249-1074 USA Suzhou Industrial Park 15-06 Peninsula Plaza Tel: +1 618.654.2341 215122 Suzhou Singapore 179098 Fax: +1 618.654.2351 P.R. CHINA Tel: +65 68.44.6445 email: info@basler.com Tel: +86 512.8227.2888 Fax: +65 68.44.8902 Fax: +86 512.8227.2887 email: singaporeinfo@basler.com email: chinainfo@basler.com...