Blocking - Siemens SIMATIC NET SCALANCE SC-600 Configuration Manual

Industrial ethernet security web based management (wbm)
Hide thumbs Also See for SIMATIC NET SCALANCE SC-600:
Table of Contents

Advertisement

Configuring with Web Based Management
4.5 "Layer 2" menu
Enabling access control for all ports
1. In the "Setting" drop-down list in Table 1, select the "Enabled" entry.
2. Click the "Copy to Table" button. The check box is enabled for all ports in table 2.
3. To apply the changes, click the "Set Values" button.
4.5.8.3

Blocking

Blocking forwarding of unknown unicast frames
On this page, you can block the forwarding of unknown unicast frames for individual
ports.
Description of the displayed values
Table 1 has the following columns:
• 1st column
Shows that the settings are valid for all ports of table 2.
• Setting
Select the setting from the drop-down list. You have the following setting options:
– Enabled
– Disabled
– No change
• Copy to Table
If you click the button, the setting is adopted for all ports of table 2.
252
Blocking of unicast frames is enabled.
Blocking of unicast frames is disabled.
Table 2 remains unchanged.
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03