Follow these recommendations for copper data cabling in high electrical noise
environments:
•
•
•
1.4.3
Supported fiber optic cables
The following fiber optic cable types are supported under the stated conditions.
Cable Type
Wavelength (nm) Modal Bandwidth
OM1 (62.5/125)
OM2 (50/125)
a
OM3 (50/125)
a
OM4 (50/125)
a
Laser optimized.
1.5
Required tools/hardware
The following tools and hardware are required to install the device:
Tools
#1 Phillips screwdriver
Slotted screwdriver
Torx T10 screwdriver
RUGGEDCOM RST2428P
Equipment Manual, 10/2023, C79000-G8976-1528-01
Cabling
1000Base-
TX Compliant
> 6
Yes
Data cable lengths should be as short as possible, preferably 3 m (10
ft) in length. Copper data cables should not be used for inter-building
communications.
Power and data cables should not be run in parallel for long distances, and
should be installed in separate conduits. Power and data cables should intersect
at 90° angles when necessary to reduce inductive coupling.
Shielded/screened cabling can be used when required. Care should be taken to
avoid the creation of ground loops with shielded cabling.
(MHz·km)
850
200
1300
500
850
500
1300
500
850
1500
1300
500
850
3500
1300
500
Tools
1.4.3 Supported fiber optic cables
Required Action
Connector and wiring standards to be determined.
Distance (m)
100Base-FX
1000Base-SX
—
2000
—
2000
—
2000
—
2000
Quantity
1
For removing/installing screw-type
terminal block plugs and the terminal
block cover.
1
For removing/installing European-style
(Euroblock) terminal block plugs.
1
For removing/installing modules.
Introduction
10GBase-SR
275
33
—
—
550
82
—
—
550
300
—
—
550
400
—
—
Detail
15