4.2
Fiber Optic Ethernet Ports
The RUGGEDCOM RSG907R features four fixed Fiber optic Ethernet ports, each with
an LC (Lucent Connector) connector. Make sure the Transmit (Tx) and Receive (Rx)
connections of each port are properly connected and matched to establish a proper
link.
Port Types
1
Tx Connector
1
Rx Connector
2
Figure 4.3
LEDs
Each port features an LED that indicates the link/activity state of the port.
Green (Solid)
Green (Blinking)
Off
Specifications
For specifications on the available fiber optic Ethernet ports, refer to
Ethernet Port Specifications (Page
4.3
SFP Transceivers
The RUGGEDCOM RSG907R supports up to three Small Form-Factor Pluggable (SFP)
transceiver sockets, which are compatible with a wide array of SFP transceivers
available from Siemens.
LEDs
Each socket features an LED that indicates its link state.
Green (Solid)
Green (Blinking)
Off
RUGGEDCOM RSG907R
Installation Manual, 02/2021, C79000-G8976-1387-12
All manuals and user guides at all-guidesbox.com
2
LC Port
State
33)".
State
Communication Ports
4.2 Fiber Optic Ethernet Ports
Description
Link established
Link activity
No link detected
Description
Link established
Activity
No link detected
"Fiber Optic
29
Need help?
Do you have a question about the SIMATIC NET RUGGEDCOM PSG907R and is the answer not in the manual?
Questions and answers