Position And Temperatures; Versions; Travel Limits - HP Designjet 3D Service Manual

Hide thumbs Also See for Designjet 3D:
Table of Contents

Advertisement

Position and Temperatures

Current Position
The current X, Y and Z position in micro steps.
X and Y = 16000 micro-steps per inch.
Z = 128000 micro-steps per inch.
Current / Total
The current build layer and the total number of layers in
the model
Layers
Current Curve
The current curve (toolpath) number of the model
Current Vertex
The current vertex (series of connected points) number of
the model.
Head Temp
The actual head temperature and its set point in C.
Head PWM
The pulse width modulation value 0 = off / 255 = 100%
Support Temp
The support liquefier temperature and its set point in C.
Support PWM
The pulse width modulation value 0 = off / 255 = 100%
Chamber Temp
The actual chamber temperature and its set point in C.

Versions

Product Version
The current version number for the complete
firmware release
Build Version
The build number for current firmware
Firmware Version
The current version for the firmware.
PLD Version
The current version of the programmable logic
devices on the controller board.
Product serial
The serial number of the complete system.
number

Travel Limits

If the box is checked the switch is tripped. NOTE: It is suggested, that due to
the time required to display switch state changes, that you use the LEDs on
the PDB to verify switch operations.
X home
The X axis home limit switch state
X Limit
The X axis end of travel limit switch state
Y Home
The Y axis home limit switch state
Y Limit
The Y axis end of travel limit switch state
Z Home
The Z axis home limit switch state
Z Limit
The Z axis end of travel limit switch state
Z Jam
The Z jam encoder switch state
Z Foam
The Z top of foam switch state.
-426