Error message on
display panel
Can't Find Home – Check
Modeling Base
Material Error
Filament error
Material Error
Filament blocked
Material Error
Carrier invalid
Material Error
Filament broken
Load Error
Filament blocked
-76
Recommendation
1. Verify a modeling base is inserted.
2. Modeling base may be used or defective
– replace.
1. Remove the carrier and verify material is
coming out of the material guide.
2. Verify material pulls freely from the carrier.
3. Verify the material tubes are free of mate-
rial.
4. Reload material.
1. Remove carrier and verify material pulls
freely from carrier.
2. Verify the material tubes are free of mate-
rial.
3. If the path is not obstructed, clean debris
from Filament Present Switch. See
"Remove debris from the Filament Present
switch" on page 64.
4. Reload material.
1. Remove carrier and verify it is not empty.
2. Replace material spool.
3. Reload material.
1. Remove the carrier and verify material is
coming out of the material guide.
2. Verify material pulls freely from the carrier.
3. Verify the material tubes are free of mate-
rial.
4. Reload material.
1. Remove the carrier and verify material is
coming out of the material guide.
2. Verify the material pulls freely from the
carrier.
3. Verify the material tubes are free of mate-
rial.
4. If the path is not obstructed, clean debris
from Filament Present Switch. See
"Remove debris from the Filament Present
switch" on page 64.
5. Reload material.