Figure 279: Umbilical hose wire tie location
Reinstall
wire tie
82. Align the left side access panel with the mounting holes.
5
83. Using a
" nut driver, reinstall the 7 left side access panel mounting
16
screws.
84. Align the right side access panel with the mounting holes.
5
85. Using a
" nut driver, reinstall the 7 right side access panel mounting
16
screws.
86. Reinstall the front cover. See
87. Reinstall the side panels. See
88. Reinstall the top panel. See
89. Power up the printer.
90. From the display panel press Maintenance > Machine > Tips.
91. Perform Z calibration. See
92. Perform XY Offset calibration. See
93. Perform Part Based calibration. See
for HP Designjet 3D with the HP Designjet 3D Diagnostic Software" on
page
352.
"Installing the front panel" on page 168
"Installing the side panels" on page 164
"Installing the top panel" on page 162
"Z Calibration" on page 338
"XY Tip Calibration" on page 340
"Performing part based calibration
-303