Figure 391: Measuring distances from outside edges of E and I
32. Measure and record the diameter of circle E along the center line
between A and I. See
Figure 392: Measuring diameter of circle E
33. Add the lengths derived from steps 30 and 31 (A-E and E-I) and then
subtract the width of circle E derived from step 32. Record this total as
"Left Front"
34. Open HP Designjet 3D Diagnostic Software and select the Current Mod-
eler from the pull down menu.
35. Open the Open Gantry Calibration Dialog box in HP Designjet 3D
Diagnostic Software.
36. In the Part Calibration section, there are six boxes: LEFT, RIGHT, FRONT,
REAR, LEFT FRONT and LEFT REAR. Enter the measurements in the
appropriate box.
37. Once the values have been entered, click on the green check mark.
38. Toggle the system power switch to accept the new values.
39. Run a test part to verify system is operating correctly.
Figure 392