Xy Tip Calibration - HP Designjet 3D Service Manual

Hide thumbs Also See for Designjet 3D:
Table of Contents

Advertisement

4. Press the Next... button.
5. Press the Next... button.
6. Press the ZT2T (Z tip to tip) button.
7. Enter the calibration value by pressing the Increment, Decrement and
8. When finished, press Done...
9. Press the Next... button until you reach the last page.
10. Press the Done... button.
1 1. Press the Save and reboot button.
12. The printer will reboot and return to idle.
13. Perform automatic Z calibration. See

XY Tip Calibration

1. Press Maintenance.
2. Press Machine.
3. Press Tip.
4. Press Calibrate XY.
5. Press Start Part. The printer will automatically build an XY Tip Calibra-
6. When the XY Tip Calibration part is complete the printer will display
7. Remove the XY Tip Calibration part from the printer.
8. Inspect the part and calibrate the X and Y axes as follows (See
9. Select Done after you have input the X and Y tip offsets. The printer will
10. Repeat steps 1-9 to verify proper calibration.
-340
Next Digit buttons.
NOTE: The value for ZT2T must be between -0.0500" and
0.0500".
tion part. (Build time is approximately 10 minutes).
Remove Part and Select XY Adjustment - X:0, Y:0
320).
A. Use the magnifier from the Startup Kit to view the support
road.
B. Identify the location on the +X or –X side of the part where
the support road is best centered within the model
boundaries.
C. Read the number closest to this location. This is the
required X Tip Offset adjustment, in mils. If the number is
on the -X side, a negative offset is required.
D. Select Increment or Decrement to input the X offset
adjustment - the value will change in the upper display
window (by default, the printer will be ready to accept the
X value).
E. Once you have entered the X offset value, Select Y and
repeat the procedure for Y Offset value.
return to Maintenance.
"Z Calibration" on page 338.